Skip to content
Haier Heat Pump Hot WaterThe Haier Heat Pump Experts in Geelong & Melbourne
This field is for validation purposes and should be left unchanged.
Heat Pumps Melbourne & Geelong

Switch to Heat Pump Hot Water!

Our friendly team is ready to help with all your enquiries and provide expert advice.

Haier Heat Pumps – Reliable Hot Water, Installed by Experts

Heat Pump Central proudly offers Haier heat pump systems, designed to deliver consistent hot water for homes across Geelong and Melbourne. With quiet operation, advanced engineering, and proven durability, Haier units perfectly suit local climates. Choosing Haier means lower energy consumption without sacrificing comfort—making it a practical investment for Australian households.

Our specialists at Heat Pump Central are dedicated to providing expert advice and precise installations, ensuring that you can upgrade your hot water system with ease and confidence. By choosing a smarter option in water heating technology, you can rely on Heat Pump Central and Haier to deliver both comfort and savings all year round. Our services are supported by extensive local installation experience, giving you peace of mind and quality assurance

Haier Heat Pump Geelong and Melbourne

Why Choose Haier Heat Pumps

Reliability & Everyday Comfort

Haier heat pumps are built for Australian households, combining robust, quiet operation with efficiency. Featuring enamel coated steel tanks, and frost protection down to -7°C, enjoy consistent, trouble-free hot water year-round, no matter the conditions.

Significant Energy Savings

Choosing Haier means cutting down on electricity bills, with savings of up to 70% compared to traditional electric water heaters. Thanks to their advanced heat-transfer technology, Haier systems maximise efficiency and reduce running costs—making them a smart investment for your wallet and the environment.

 

Smart & Easy Control

Manage your hot water with ease through Haier’s intuitive Smart Wi-Fi controller. Adjust temperature settings remotely, schedule heating times, and monitor energy usage right from your smartphone. Haier puts full control of your hot water needs at your fingertips.

HAIER Promo Website Banner

View the Terms & Conditions on Haier’s website by clicking here.

Product Review's 2025 Awards Winner

Unlike standard heat pumps, Haier models feature whisper-quiet operation, making them perfect for residential areas where noise can be a concern. Their innovative Smart Boost technology ensures rapid water heating while maintaining outstanding energy savings. Designed specifically for Australian climates, Haier pumps use eco-friendly refrigerants with low global warming potential, significantly reducing environmental impact.

With robust build quality backed by comprehensive warranties, Haier heat pumps deliver lasting comfort and lower running costs. Choose Haier to experience unmatched reliability, sustainability, and performance from your hot water system.

Discover the Power of Haier Heat Pump Water Heaters

Haier Heat Pump Models & Specifications

Model HP200M1-U1

Specification Details
Total water capacity 195L
Rated voltage / frequency 220-240V / 50Hz
PTR setting 700kPa
Ingress protection IPX4
Hot & cold inlet connections ¾” RP
PTR connection ¾” RP
COP* @ 20°C/15°C 4.49
Power input of electric element 1.5kW
Rated power input of heat pump 0.43kW
Maximum power input of heat pump 0.75kW
Maximum power input of the appliance 2.25kW
Average heating capacity by heat pump 2.0kW
Default temperature setting 60°C
Heating range (with element) 35°C – 75°C
Heating range (heat pump only) 35°C – 65°C
Refrigerant type / weight R290 / 0.34kg
Noise 43dB(A)
Ambient temperature range -7~45°C
Tank Warranty 7 years
Parts & Labour Warranty 5 years

Model HP250M1-U1

Specification Details
Total water capacity 246L
Rated voltage / frequency 220-240V / 50Hz
PTR setting 700kPa
Ingress protection IPX4
Hot & cold inlet connections ¾” RP
PTR connection ¾” RP
COP* @ 20°C/15°C 4.48
Power input of electric element 1.5kW
Rated power input of heat pump 0.43kW
Maximum power input of heat pump 0.75kW
Maximum power input of the appliance 2.25kW
Average heating capacity by heat pump 2.0kW
Default temperature setting 60°C
Heating range (with element) 35°C – 75°C
Heating range (heat pump only) 35°C – 65°C
Refrigerant type / weight R290 / 0.34kg
Noise 43dB(A)
Ambient temperature range -7~45°C
Tank Warranty 7 years
Parts & Labour Warranty 5 years
Haier 330L Heat Pump

Model HP330M1U1

Specification Details
Total water capacity 330L
Rated voltage / frequency 220–240V / 50Hz
Maximum pressure 850kPa
Corrosion protection Magnesium rod
Ingress protection IP24
COP* @ 20°C/15°C 4.00
Power input of electric element 2.2kW
Rated power input of compressor 0.7kW
Power input range of compressor 0.2 to 1.2kW
Maximum power input (total appliance) 3.4kW
Rated heating capacity (compressor) 2.8kW
Heating water capacity 60L/hr
Heating up time* 5.5h
Default temperature setting 60°C
Heating range (with heater) 35°C – 75°C
Max temperature of the heat pump only 65°C
Max working pressure of refrigerant 1.0/3.3MPa
Refrigerant type / weight R290 / 0.47kg
Noise level @ 1m 47dB(A)
Ambient temperature range (appliance) -7°C to 45°C
Ambient temperature range (heat pump) -7°C to 45°C
Water inlet and outlet connection Rp ¾”
PTR valve connection Rp ¾”
Product dimensions 710×758×1941mm
Packing dimensions with pallet 745×745×2263mm
Net / Gross weight 122kg / 150kg
Filled weight 452kg
Tank Warranty 7 years
Parts & Labour Warranty 5 years
Haier Split System Heat Pump Water Heater Model HP300S2-F7

Model HP300S2-F7

Specification Details
Total water capacity 276L
Rated voltage / frequency 220-240V / 50Hz
PTR setting 700kPa
Ingress protection IPX4
Hot & cold inlet connections ¾” RP
PTR connection ¾” RP
COP* @ 20°C/15°C 4.48
Power input of electric element 2.6kW
Rated power input of appliance 4.3kW
Average power input of the heat pump 1.19kW
Pair coil tube and connection size – Liquid line 1/4″ (6.35mm) / (7/16 – 20UNF)
Pair coil tube and connection size – Suction line 3/8″ (9.52mm) / (5/8 – 18UNF)
Maximum power input of the heat pump 1.7kW
Average heating capacity of the heat pump 4.58kW
Default temperature setting 55°C
Heating range (with element) 35°C – 75°C
Heating range (heat pump only) 35°C – 55°C
Refrigerant type / weight R32 / 0.93kg
Refrigerant pipe length Min. 1m – Max. 3m
Noise 52dB(A)
Ambient temperature range -15~45°C
Tank Warranty 7 years
Parts & Labour Warranty 5 years